OSFP 800G Pluggable Transceivers

OSFP 800G transceivers: DR8, 2×DR4, DR8+, DR8++, 2×FR4, 2×LR4 and VR8. 50 m multimode to 10 km single-mode.
  • 800G in one OSFP port, as one 800G link or two 400G links
  • Reach: 50 m (OM4), 500 m, 2 km and 10 km (single-mode)
  • Dual MPO-12 or dual duplex LC connectors
  • Coding for NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, generic or custom
  • Finned top for high-density switch ports
  • OSFP MSA, CMIS 5.x host management

Engineered to Outperform

Delivered with Certainty

Procurement Made Simple

Rapid Deployment Ready

Ready To Scale

Compliance Assured

OSFP 800G transceivers have 8 electrical lanes at 100G PAM4. All modules in the range use the same finned OSFP body. Select the module for the link length, from 50 m on multimode fibre to 10 km on single-mode fibre.

DR8 and 2×DR4 operate over 500 m on two MPO-12 connectors. DR8 is one 800G link. 2×DR4 is two independent 400G links. DR8+ (2 km) and DR8++ (10 km) use the same two MPO-12 connectors. 2×FR4 (2 km) and 2×LR4 (10 km) are twin-port modules with two duplex LC connectors. VR8 operates over 50 m of OM4 multimode fibre. All modules operate from 0 °C to +70 °C.

Coding: each module is listed with NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) and generic (-CG) coding. Custom coding is available on request. The coding changes only the EEPROM identity.

For carrier and data centre operators in Africa. Use these 800G modules for links from 50 m (multimode) to 10 km (single-mode).
Electrical
Host InterfaceOSFP (8 lanes × 100G PAM4)
Power ConsumptionDR8+: <16 W
DR8++: <18.5 W
2×FR4: <16 W
VR8: <13.5 W
Other variants: see datasheet
Optical
WavelengthsDR8, 2×DR4, DR8+, DR8++: 1310 nm
2×FR4, 2×LR4: CWDM4 (1271 / 1291 / 1311 / 1331 nm)
VR8: 850 nm VCSEL
ReachVR8: 50 m OM4 / 30 m OM3
DR8, 2×DR4: 500 m SMF
DR8+, 2×FR4: 2 km SMF
DR8++, 2×LR4: 10 km SMF
Fibre TypeOS2 single-mode (all except VR8)
OM3 / OM4 multimode (VR8)
ConnectorsDual MPO-12 (DR8, 2×DR4, DR8+, DR8++)
Dual MPO-12 APC (VR8)
Dual duplex LC (2×FR4, 2×LR4)
Media Standards800GBASE-DR8 / 2×400GBASE-DR4 (IEEE 802.3df)
2×400GBASE-FR4 (IEEE 802.3cu)
2×400G-LR4-10 (100G Lambda MSA)
VR8: 2×400GBASE-SR4 (IEEE 802.3db)
Protocol Support
Ethernet800 GbE, or 2 × 400 GbE (twin-port variants)
Coding & Compatibility
Standard CodingsNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), generic (-CG). The optical module is the same for each coding. Only the EEPROM identity is different.
Custom CodingAvailable on request for other switch vendors.
Environmental
Operating Temperature0 °C to +70 °C (Commercial)
Storage Temperature-40 °C to +85 °C
MSA ComplianceOSFP MSA Rev 5.0+
Compliance
StandardsIEEE 802.3cu / 802.3db / 802.3df, 100G Lambda MSA, OSFP MSA, CMIS 5.x, RoHS3
RoHS CompliantYes
OSFP 800G DR8 (Dual MPO-12, single-mode)
Part NumberDescription
PO-OS-800GE-DR8-2MPO-FN-CNOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, NVIDIA-coded
PO-OS-800GE-DR8-2MPO-FN-CCOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Cisco-coded
PO-OS-800GE-DR8-2MPO-FN-CJOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Juniper-coded
PO-OS-800GE-DR8-2MPO-FN-CAOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Arista-coded
PO-OS-800GE-DR8-2MPO-FN-CHOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-DR8-2MPO-FN-CDOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Dell-coded
PO-OS-800GE-DR8-2MPO-FN-CFOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Fortinet-coded
PO-OS-800GE-DR8-2MPO-FN-CGOSFP 800G DR8, Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, generic (uncoded)
OSFP 800G 2×DR4 Twin-Port (Dual MPO-12, single-mode)
Part NumberDescription
PO-OS-800GE-2DR4-2MPO-FN-CNOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, NVIDIA-coded
PO-OS-800GE-2DR4-2MPO-FN-CCOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Cisco-coded
PO-OS-800GE-2DR4-2MPO-FN-CJOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Juniper-coded
PO-OS-800GE-2DR4-2MPO-FN-CAOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Arista-coded
PO-OS-800GE-2DR4-2MPO-FN-CHOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-2DR4-2MPO-FN-CDOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Dell-coded
PO-OS-800GE-2DR4-2MPO-FN-CFOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, Fortinet-coded
PO-OS-800GE-2DR4-2MPO-FN-CGOSFP 800G 2×DR4 Twin-Port (2 × 400G), Dual MPO-12, Ethernet, Finned, 1310 nm, 500 m SMF, 0–70 °C, generic (uncoded)
OSFP 800G DR8+ Extended Reach (Dual MPO-12, single-mode)
Part NumberDescription
PO-OS-800GE-DR8K2-2MPO-FN-CNOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, NVIDIA-coded
PO-OS-800GE-DR8K2-2MPO-FN-CCOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Cisco-coded
PO-OS-800GE-DR8K2-2MPO-FN-CJOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Juniper-coded
PO-OS-800GE-DR8K2-2MPO-FN-CAOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Arista-coded
PO-OS-800GE-DR8K2-2MPO-FN-CHOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-DR8K2-2MPO-FN-CDOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Dell-coded
PO-OS-800GE-DR8K2-2MPO-FN-CFOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, Fortinet-coded
PO-OS-800GE-DR8K2-2MPO-FN-CGOSFP 800G DR8+, Dual MPO-12, Ethernet, Finned, 1310 nm, 2 km SMF, <16 W, 0–70 °C, generic (uncoded)
OSFP 800G DR8++ Long Reach (Dual MPO-12, single-mode)
Part NumberDescription
PO-OS-800GE-DR8K10-2MPO-FN-CNOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, NVIDIA-coded
PO-OS-800GE-DR8K10-2MPO-FN-CCOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Cisco-coded
PO-OS-800GE-DR8K10-2MPO-FN-CJOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Juniper-coded
PO-OS-800GE-DR8K10-2MPO-FN-CAOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Arista-coded
PO-OS-800GE-DR8K10-2MPO-FN-CHOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-DR8K10-2MPO-FN-CDOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Dell-coded
PO-OS-800GE-DR8K10-2MPO-FN-CFOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, Fortinet-coded
PO-OS-800GE-DR8K10-2MPO-FN-CGOSFP 800G DR8++, Dual MPO-12, Ethernet, Finned, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, generic (uncoded)
OSFP 800G 2×FR4 CWDM4 Twin-Port (Dual Duplex LC, single-mode)
Part NumberDescription
PO-OS-800GE-2FR4-2LC-CNOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, NVIDIA-coded
PO-OS-800GE-2FR4-2LC-CCOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Cisco-coded
PO-OS-800GE-2FR4-2LC-CJOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Juniper-coded
PO-OS-800GE-2FR4-2LC-CAOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Arista-coded
PO-OS-800GE-2FR4-2LC-CHOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-2FR4-2LC-CDOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Dell-coded
PO-OS-800GE-2FR4-2LC-CFOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, Fortinet-coded
PO-OS-800GE-2FR4-2LC-CGOSFP 800G 2×FR4 CWDM4, Dual Duplex LC, Ethernet, 2 km SMF, <16 W, 0–70 °C, generic (uncoded)
OSFP 800G 2×LR4 Twin-Port (Dual Duplex LC, single-mode)
Part NumberDescription
PO-OS-800GE-2LR4-2LC-FN-CNOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, NVIDIA-coded
PO-OS-800GE-2LR4-2LC-FN-CCOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Cisco-coded
PO-OS-800GE-2LR4-2LC-FN-CJOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Juniper-coded
PO-OS-800GE-2LR4-2LC-FN-CAOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Arista-coded
PO-OS-800GE-2LR4-2LC-FN-CHOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-2LR4-2LC-FN-CDOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Dell-coded
PO-OS-800GE-2LR4-2LC-FN-CFOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, Fortinet-coded
PO-OS-800GE-2LR4-2LC-FN-CGOSFP 800G 2×LR4, Dual Duplex LC, Ethernet, Finned, CWDM4, 10 km SMF, 0–70 °C, generic (uncoded)
OSFP 800G VR8 Multimode (2×400G SR4, Dual MPO-12 APC)
Part NumberDescription
PO-OS-800GE-VR8-2MPO-CNOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, NVIDIA-coded
PO-OS-800GE-VR8-2MPO-CCOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Cisco-coded
PO-OS-800GE-VR8-2MPO-CJOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Juniper-coded
PO-OS-800GE-VR8-2MPO-CAOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Arista-coded
PO-OS-800GE-VR8-2MPO-CHOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, HPE / Aruba-coded
PO-OS-800GE-VR8-2MPO-CDOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Dell-coded
PO-OS-800GE-VR8-2MPO-CFOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, Fortinet-coded
PO-OS-800GE-VR8-2MPO-CGOSFP 800G VR8 (2×400G SR4) Multimode, Dual MPO-12 APC, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, generic (uncoded)