Na'urorin Transceiver Masu Toshewa na QSFP-DD 200G

Na'urorin transceiver na QSFP-DD 200G: SR8, SR4, FR4, LR4, LR8 da PSM8. 100 m multimode zuwa 10 km single-mode.
  • 200G a cikin tashar QSFP-DD ɗaya, mahaɗar host ta 8 × 25G NRZ
  • Nisa: 100 m (OM4), 2 km da 10 km (single-mode)
  • Ana iya raba SR8 da PSM8 zuwa 2 × 100G ko 8 × 25G (idan tashar switch tana tallafawa)
  • MPO-24 (SR8), MPO-24 APC (PSM8), MPO-12 (SR4) ko duplex LC (FR4, LR4, LR8)
  • Lambar tantancewa don NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, ta gama-gari ko ta musamman
  • Kewayon zafin kasuwanci: 0 °C zuwa +70 °C
  • QSFP-DD MSA, sarrafa host na CMIS

An Ƙera Don Zarcewa

An Bayar da Tabbatacce

Saye Ya Zama Sauƙi

Shirye Don Gaggauta Tura

Shirye Don Faɗaɗawa

Bin Ka’ida Tabbas

Na'urorin transceiver na QSFP-DD 200G suna da layukan lantarki 8 na 25G NRZ. Yi amfani da su a tashoshin switch na QSFP-DD da ke aiki a 200G.

SR8 da PSM8 suna da layuka takwas masu layi ɗaya-ɗaya na 25G. Idan tashar switch tana tallafawa, kuna iya raba kowannensu zuwa 2 × 100G ko 8 × 25G. SR8 tana aiki har zuwa 100 m a kan fiber na multimode na OM4 ta mahaɗin MPO-24. PSM8 tana aiki har zuwa 10 km a kan fiber na single-mode ta mahaɗin MPO-24 APC.

SR4, FR4 da LR4 suna da layukan haske 4 na 50G PAM4. SR4 tana aiki har zuwa 100 m a kan OM4 ta mahaɗin MPO-12. FR4 (2 km) da LR4 (10 km) suna amfani da mahaɗin duplex LC ɗaya. LR8 tana aiki har zuwa 10 km a kan tsawon raƙuman haske 8 da mahaɗin duplex LC ɗaya. Dukkan na'urori suna aiki daga 0 °C zuwa +70 °C.

Lambar tantancewa: an jera kowace na'ura da lambar tantancewa ta NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) da ta gama-gari (-CG). Ana samun lambar tantancewa ta musamman idan an buƙata. Lambar tantancewa tana canza shaidar EEPROM kawai.

Don kamfanonin sadarwa da masu gudanar da cibiyoyin bayanai a Afirka. Yi amfani da waɗannan na’urorin 200G a tashoshin switch na QSFP-DD, daga 100 m (multimode) zuwa 10 km (single-mode).
Lantarki
Mahaɗar HostQSFP-DD (layuka 8 × 25G NRZ)
Sigina8 × 25G NRZ na haske (SR8, LR8, PSM8)
4 × 50G PAM4 na haske tare da gearbox na ciki (SR4, FR4, LR4)
Amfani da WutaPSM8: <6.5 W
Sauran nau'o'i: duba takardar bayanai
Haske
Tsawon Raƙuman HaskeSR8, SR4: 850 nm VCSEL
PSM8: 1310 nm
FR4: CWDM4 (1271 / 1291 / 1311 / 1331 nm)
LR4: LAN-WDM (1295.56 / 1300.05 / 1304.58 / 1309.14 nm)
LR8: LAN-WDM mai lambda 8 (1273–1310 nm)
NisaSR8, SR4: 100 m OM4 (70 m OM3)
FR4: 2 km SMF
LR4, LR8, PSM8: 10 km SMF
Nau'in FiberOM3 / OM4 multimode (SR8, SR4)
OS2 single-mode (FR4, LR4, LR8, PSM8)
MahaɗaiMPO-24 (SR8)
MPO-24 APC (PSM8)
MPO-12 (SR4)
Duplex LC (FR4, LR4, LR8)
Ma'aunin MediaSR8: 2 × 100GBASE-SR4 (IEEE 802.3bm)
200GBASE-SR4 (IEEE 802.3cd)
200GBASE-FR4 / LR4 (IEEE 802.3bs)
LR8, PSM8: ma'aunin masana'antu
Tallafin Yarjejeniya (Protocol)
Ethernet200 GbE. SR8 da PSM8: rarrabawa zuwa 2 × 100 GbE ko 8 × 25 GbE idan tashar switch tana tallafawa
Lambar Tantancewa da Jituwa
Daidaitattun Lambobin TantancewaNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), ta gama-gari (-CG). Na'urar haske ɗaya ce ga kowace lambar tantancewa. Shaidar EEPROM kawai ce ta bambanta.
Lambar Tantancewa ta MusammanAna samu idan an buƙata don sauran masu ƙera switch.
Muhalli
Zafin Aiki0 °C zuwa +70 °C (Kasuwanci)
Zafin Ajiya-40 °C zuwa +85 °C
Bin MSAQSFP-DD MSA
Bin Ƙa'idoji
Ma'auniIEEE 802.3bm / 802.3bs / 802.3cd, QSFP-DD MSA, CMIS, RoHS3
Ya bi RoHSEe
QSFP-DD 200G SR8 Multimode (MPO-24)
Lambar SasheBayani
PO-QDD-200GE-SR8-MP24-CNQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-SR8-MP24-CCQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-SR8-MP24-CJQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-SR8-MP24-CAQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-SR8-MP24-CHQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-SR8-MP24-CDQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-SR8-MP24-CFQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-SR8-MP24-CGQSFP-DD 200 GbE SR8, MPO-24, 850 nm, 8 × 25G NRZ, 100 m OM4 / 70 m OM3, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP-DD 200G SR4 Multimode (MPO-12)
Lambar SasheBayani
PO-QDD-200GE-SR4-MPO-CNQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-SR4-MPO-CCQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-SR4-MPO-CJQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-SR4-MPO-CAQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-SR4-MPO-CHQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-SR4-MPO-CDQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-SR4-MPO-CFQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-SR4-MPO-CGQSFP-DD 200 GbE SR4, MPO-12, 850 nm, 4 × 50G PAM4, 100 m OM4 / 70 m OM3, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP-DD 200G FR4 CWDM4 (Duplex LC, single-mode)
Lambar SasheBayani
PO-QDD-200GE-FR4-LC-CNQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-FR4-LC-CCQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-FR4-LC-CJQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-FR4-LC-CAQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-FR4-LC-CHQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-FR4-LC-CDQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-FR4-LC-CFQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-FR4-LC-CGQSFP-DD 200 GbE FR4, Duplex LC, CWDM4, 4 × 50G PAM4, 2 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP-DD 200G LR4 (Duplex LC, single-mode)
Lambar SasheBayani
PO-QDD-200GE-LR4-LC-CNQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-LR4-LC-CCQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-LR4-LC-CJQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-LR4-LC-CAQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-LR4-LC-CHQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-LR4-LC-CDQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-LR4-LC-CFQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-LR4-LC-CGQSFP-DD 200 GbE LR4, Duplex LC, LAN-WDM, 4 × 50G PAM4, 10 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP-DD 200G LR8 (Duplex LC, single-mode)
Lambar SasheBayani
PO-QDD-200GE-LR8-LC-CNQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-LR8-LC-CCQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-LR8-LC-CJQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-LR8-LC-CAQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-LR8-LC-CHQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-LR8-LC-CDQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-LR8-LC-CFQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-LR8-LC-CGQSFP-DD 200 GbE LR8, Duplex LC, LAN-WDM mai lambda 8, 8 × 25G NRZ, 10 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP-DD 200G PSM8 (MPO-24 APC, single-mode mai layi ɗaya-ɗaya)
Lambar SasheBayani
PO-QDD-200GE-PSM8K10-MP24-CNQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-QDD-200GE-PSM8K10-MP24-CCQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-QDD-200GE-PSM8K10-MP24-CJQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-QDD-200GE-PSM8K10-MP24-CAQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta Arista
PO-QDD-200GE-PSM8K10-MP24-CHQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-QDD-200GE-PSM8K10-MP24-CDQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta Dell
PO-QDD-200GE-PSM8K10-MP24-CFQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-QDD-200GE-PSM8K10-MP24-CGQSFP-DD 200 GbE PSM8, MPO-24 APC, 1310 nm, 8 × 25G NRZ masu layi ɗaya (parallel), 10 km SMF, <6.5 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)