Na'urorin Transceiver Masu Toshewa na QSFP112 400G

Na'urorin transceiver na QSFP112 400G: DR4, FR4, LR4 da SR4. 100 m multimode zuwa 10 km single-mode.
  • 400G a cikin jikin QSFP112 mai yawa ɗaya (single-density)
  • Nisa: 100 m (OM4), 500 m, 2 km da 10 km (single-mode)
  • MPO-12 (DR4), MPO-12 APC (SR4) ko duplex LC (FR4, LR4)
  • Lambar tantancewa don NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, ta gama-gari ko ta musamman
  • Kewayon zafin kasuwanci: 0 °C zuwa +70 °C
  • QSFP112 MSA, sarrafa host na CMIS 5.x

An Ƙera Don Zarcewa

An Bayar da Tabbatacce

Saye Ya Zama Sauƙi

Shirye Don Gaggauta Tura

Shirye Don Faɗaɗawa

Bin Ka’ida Tabbas

Na'urorin transceiver na QSFP112 400G suna da layukan lantarki 4 na 100G PAM4 a cikin jikin QSFP mai yawa ɗaya (single-density). Yi amfani da su a tashoshin switch na QSFP112 da adaftocin hanyar sadarwa.

DR4 tana aiki har zuwa 500 m a kan fiber na single-mode ta mahaɗin MPO-12 ɗaya. FR4 (2 km) da LR4 (10 km) suna amfani da mahaɗin duplex LC ɗaya. SR4 tana aiki har zuwa 100 m a kan fiber na multimode na OM4 ta mahaɗin MPO-12 APC. Ana samun SR4 don InfiniBand da Ethernet, ko don Ethernet kawai. Dukkan na'urori suna aiki daga 0 °C zuwa +70 °C.

Lambar tantancewa: an jera kowace na'ura da lambar tantancewa ta NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) da ta gama-gari (-CG). Ana samun lambar tantancewa ta musamman idan an buƙata. Lambar tantancewa tana canza shaidar EEPROM kawai.

Don kamfanonin sadarwa da masu gudanar da cibiyoyin bayanai a Afirka. Yi amfani da waɗannan na’urorin 400G don hanyoyin haɗin switch da adaftocin hanyar sadarwa daga 100 m (multimode) zuwa 10 km (single-mode).
Lantarki
Mahaɗar HostQSFP112 (layuka 4 × 100G PAM4)
SiginaPAM4 na 100G a kowane layi
Amfani da WutaSR4: <8 W
DR4, FR4, LR4: duba takardar bayanai
Haske
Tsawon Raƙuman HaskeDR4: 1310 nm
FR4, LR4: CWDM (1271 / 1291 / 1311 / 1331 nm)
SR4: 850 nm VCSEL
NisaSR4: 100 m OM4
DR4: 500 m SMF
FR4: 2 km SMF
LR4: 10 km SMF
Nau'in FiberOS2 single-mode (DR4, FR4, LR4)
OM4 multimode (SR4)
MahaɗaiMPO-12 (DR4)
MPO-12 APC (SR4)
Duplex LC (FR4, LR4)
Ma'aunin Media400GBASE-DR4 (IEEE 802.3bs)
400GBASE-FR4 (IEEE 802.3cu)
400G-LR4-10 (100G Lambda MSA)
400GBASE-SR4 (IEEE 802.3db)
Tallafin Yarjejeniya (Protocol)
Ethernet400 GbE (dukkan SKU)
InfiniBandNDR (nau'in SR4 IB+ETH kawai)
Lambar Sashe ta Nuni ta NVIDIAMMS1X00-NS400 (DR4)
MMA1Z00-NS400 (SR4 IB+ETH)
MMA1Z00-NS400-T (SR4 ETH)
Lambar Tantancewa da Jituwa
Daidaitattun Lambobin TantancewaNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), ta gama-gari (-CG). Na'urar haske ɗaya ce ga kowace lambar tantancewa. Shaidar EEPROM kawai ce ta bambanta.
Lambar Tantancewa ta MusammanAna samu idan an buƙata don sauran masu ƙera switch.
Muhalli
Zafin Aiki0 °C zuwa +70 °C (Kasuwanci)
Zafin Ajiya-40 °C zuwa +85 °C
Bin MSAQSFP112 MSA
Bin Ƙa'idoji
Ma'auniIEEE 802.3bs / 802.3cu / 802.3db, 100G Lambda MSA, QSFP112 MSA, CMIS 5.x, RoHS3
Ya bi RoHSEe
QSFP112 400G DR4 (MPO-12, single-mode)
Lambar SasheBayani
PO-112-400GE-DR4-MPO-CNQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta NVIDIA (lambar nuni MMS1X00-NS400)
PO-112-400GE-DR4-MPO-CCQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-112-400GE-DR4-MPO-CJQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-112-400GE-DR4-MPO-CAQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-112-400GE-DR4-MPO-CHQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-112-400GE-DR4-MPO-CDQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-112-400GE-DR4-MPO-CFQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-112-400GE-DR4-MPO-CGQSFP112 400G DR4, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP112 400G FR4 CWDM4 (Duplex LC, single-mode)
Lambar SasheBayani
PO-112-400GE-FR4-LC-CNQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-112-400GE-FR4-LC-CCQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-112-400GE-FR4-LC-CJQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-112-400GE-FR4-LC-CAQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-112-400GE-FR4-LC-CHQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-112-400GE-FR4-LC-CDQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-112-400GE-FR4-LC-CFQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-112-400GE-FR4-LC-CGQSFP112 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP112 400G LR4 (Duplex LC, single-mode)
Lambar SasheBayani
PO-112-400GE-LR4-LC-CNQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-112-400GE-LR4-LC-CCQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-112-400GE-LR4-LC-CJQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-112-400GE-LR4-LC-CAQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-112-400GE-LR4-LC-CHQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-112-400GE-LR4-LC-CDQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-112-400GE-LR4-LC-CFQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-112-400GE-LR4-LC-CGQSFP112 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
QSFP112 400G SR4 Multimode (MPO-12 APC)
Lambar SasheBayani
PO-112-400GIE-SR4-MPO-CNQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta NVIDIA (lambar nuni MMA1Z00-NS400)
PO-112-400GIE-SR4-MPO-CCQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-112-400GIE-SR4-MPO-CJQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-112-400GIE-SR4-MPO-CAQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Arista
PO-112-400GIE-SR4-MPO-CHQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-112-400GIE-SR4-MPO-CDQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Dell
PO-112-400GIE-SR4-MPO-CFQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-112-400GIE-SR4-MPO-CGQSFP112 400G SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
PO-112-400GE-SR4-MPO-CNQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta NVIDIA (lambar nuni MMA1Z00-NS400-T)
PO-112-400GE-SR4-MPO-CCQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-112-400GE-SR4-MPO-CJQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-112-400GE-SR4-MPO-CAQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Arista
PO-112-400GE-SR4-MPO-CHQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-112-400GE-SR4-MPO-CDQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Dell
PO-112-400GE-SR4-MPO-CFQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-112-400GE-SR4-MPO-CGQSFP112 400G SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 100 m OM4, <8 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)