- 800G a cikin tashar OSFP ɗaya, a matsayin hanyar haɗi ɗaya ta 800G ko hanyoyin haɗi biyu na 400G
- Nisa: 50 m (OM4), 500 m, 2 km da 10 km (single-mode)
- Mahaɗan MPO-12 biyu ko duplex LC biyu
- Lambar tantancewa don NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, ta gama-gari ko ta musamman
- Saman mai fikafikan sanyaya don tashoshin switch masu yawan tashoshi
- OSFP MSA, sarrafa host na CMIS 5.x
An Ƙera Don Zarcewa
An Bayar da Tabbatacce
Saye Ya Zama Sauƙi
Shirye Don Gaggauta Tura
Shirye Don Faɗaɗawa
Bin Ka’ida Tabbas
Na'urorin transceiver na OSFP 800G suna da layukan lantarki 8 na 100G PAM4. Dukkan na'urorin da ke cikin jerin suna amfani da jikin OSFP ɗaya mai fikafikan sanyaya. Zaɓi na'urar bisa tsawon hanyar haɗi, daga 50 m a kan fiber na multimode zuwa 10 km a kan fiber na single-mode.
DR8 da 2×DR4 suna aiki har zuwa 500 m ta mahaɗan MPO-12 guda biyu. DR8 hanyar haɗi ɗaya ce ta 800G. 2×DR4 hanyoyin haɗi biyu ne masu zaman kansu na 400G. DR8+ (2 km) da DR8++ (10 km) suna amfani da mahaɗan MPO-12 guda biyu iri ɗaya. 2×FR4 (2 km) da 2×LR4 (10 km) na'urorin twin-port ne masu mahaɗan duplex LC guda biyu. VR8 tana aiki har zuwa 50 m a kan fiber na multimode na OM4. Dukkan na'urori suna aiki daga 0 °C zuwa +70 °C.
Lambar tantancewa: an jera kowace na'ura da lambar tantancewa ta NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) da ta gama-gari (-CG). Ana samun lambar tantancewa ta musamman idan an buƙata. Lambar tantancewa tana canza shaidar EEPROM kawai.
| Lantarki | |
| Mahaɗar Host | OSFP (layuka 8 × 100G PAM4) |
| Amfani da Wuta | DR8+: <16 W DR8++: <18.5 W 2×FR4: <16 W VR8: <13.5 W Sauran nau'o'i: duba takardar bayanai |
| Haske | |
| Tsawon Raƙuman Haske | DR8, 2×DR4, DR8+, DR8++: 1310 nm 2×FR4, 2×LR4: CWDM4 (1271 / 1291 / 1311 / 1331 nm) VR8: 850 nm VCSEL |
| Nisa | VR8: 50 m OM4 / 30 m OM3 DR8, 2×DR4: 500 m SMF DR8+, 2×FR4: 2 km SMF DR8++, 2×LR4: 10 km SMF |
| Nau'in Fiber | OS2 single-mode (dukkan banda VR8) OM3 / OM4 multimode (VR8) |
| Mahaɗai | MPO-12 biyu (DR8, 2×DR4, DR8+, DR8++) MPO-12 APC biyu (VR8) Duplex LC biyu (2×FR4, 2×LR4) |
| Ma'aunin Media | 800GBASE-DR8 / 2×400GBASE-DR4 (IEEE 802.3df) 2×400GBASE-FR4 (IEEE 802.3cu) 2×400G-LR4-10 (100G Lambda MSA) VR8: 2×400GBASE-SR4 (IEEE 802.3db) |
| Tallafin Yarjejeniya (Protocol) | |
| Ethernet | 800 GbE, ko 2 × 400 GbE (nau'o'in twin-port) |
| Lambar Tantancewa da Jituwa | |
| Daidaitattun Lambobin Tantancewa | NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), ta gama-gari (-CG). Na'urar haske ɗaya ce ga kowace lambar tantancewa. Shaidar EEPROM kawai ce ta bambanta. |
| Lambar Tantancewa ta Musamman | Ana samu idan an buƙata don sauran masu ƙera switch. |
| Muhalli | |
| Zafin Aiki | 0 °C zuwa +70 °C (Kasuwanci) |
| Zafin Ajiya | -40 °C zuwa +85 °C |
| Bin MSA | OSFP MSA Rev 5.0+ |
| Bin Ƙa'idoji | |
| Ma'auni | IEEE 802.3cu / 802.3db / 802.3df, 100G Lambda MSA, OSFP MSA, CMIS 5.x, RoHS3 |
| Ya bi RoHS | Ee |
| OSFP 800G DR8 (MPO-12 biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-DR8-2MPO-FN-CN | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-DR8-2MPO-FN-CC | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-DR8-2MPO-FN-CJ | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-DR8-2MPO-FN-CA | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-DR8-2MPO-FN-CH | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-DR8-2MPO-FN-CD | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-DR8-2MPO-FN-CF | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-DR8-2MPO-FN-CG | OSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G 2×DR4 Twin-Port (MPO-12 biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-2DR4-2MPO-FN-CN | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-2DR4-2MPO-FN-CC | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-2DR4-2MPO-FN-CJ | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-2DR4-2MPO-FN-CA | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-2DR4-2MPO-FN-CH | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-2DR4-2MPO-FN-CD | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-2DR4-2MPO-FN-CF | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-2DR4-2MPO-FN-CG | OSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G DR8+ Ƙarin Nisa (MPO-12 biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-DR8K2-2MPO-FN-CN | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-DR8K2-2MPO-FN-CC | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-DR8K2-2MPO-FN-CJ | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-DR8K2-2MPO-FN-CA | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-DR8K2-2MPO-FN-CH | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-DR8K2-2MPO-FN-CD | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-DR8K2-2MPO-FN-CF | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-DR8K2-2MPO-FN-CG | OSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G DR8++ Nisa Mai Tsawo (MPO-12 biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-DR8K10-2MPO-FN-CN | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-DR8K10-2MPO-FN-CC | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-DR8K10-2MPO-FN-CJ | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-DR8K10-2MPO-FN-CA | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-DR8K10-2MPO-FN-CH | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-DR8K10-2MPO-FN-CD | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-DR8K10-2MPO-FN-CF | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-DR8K10-2MPO-FN-CG | OSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G 2×FR4 CWDM4 Twin-Port (Duplex LC biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-2FR4-2LC-CN | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-2FR4-2LC-CC | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-2FR4-2LC-CJ | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-2FR4-2LC-CA | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-2FR4-2LC-CH | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-2FR4-2LC-CD | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-2FR4-2LC-CF | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-2FR4-2LC-CG | OSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G 2×LR4 Twin-Port (Duplex LC biyu, single-mode) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-2LR4-2LC-FN-CN | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-2LR4-2LC-FN-CC | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-2LR4-2LC-FN-CJ | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-2LR4-2LC-FN-CA | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-2LR4-2LC-FN-CH | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-2LR4-2LC-FN-CD | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-2LR4-2LC-FN-CF | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-2LR4-2LC-FN-CG | OSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |
| OSFP 800G VR8 Multimode (2×400G SR4, MPO-12 APC biyu) | |
| Lambar Sashe | Bayani |
| PO-OS-800GE-VR8-2MPO-CN | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta NVIDIA |
| PO-OS-800GE-VR8-2MPO-CC | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Cisco |
| PO-OS-800GE-VR8-2MPO-CJ | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Juniper |
| PO-OS-800GE-VR8-2MPO-CA | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Arista |
| PO-OS-800GE-VR8-2MPO-CH | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba |
| PO-OS-800GE-VR8-2MPO-CD | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Dell |
| PO-OS-800GE-VR8-2MPO-CF | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Fortinet |
| PO-OS-800GE-VR8-2MPO-CG | OSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba) |















