Na'urorin Transceiver Masu Toshewa na OSFP 800G

Na'urorin transceiver na OSFP 800G: DR8, 2×DR4, DR8+, DR8++, 2×FR4, 2×LR4 da VR8. 50 m multimode zuwa 10 km single-mode.
  • 800G a cikin tashar OSFP ɗaya, a matsayin hanyar haɗi ɗaya ta 800G ko hanyoyin haɗi biyu na 400G
  • Nisa: 50 m (OM4), 500 m, 2 km da 10 km (single-mode)
  • Mahaɗan MPO-12 biyu ko duplex LC biyu
  • Lambar tantancewa don NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, ta gama-gari ko ta musamman
  • Saman mai fikafikan sanyaya don tashoshin switch masu yawan tashoshi
  • OSFP MSA, sarrafa host na CMIS 5.x

An Ƙera Don Zarcewa

An Bayar da Tabbatacce

Saye Ya Zama Sauƙi

Shirye Don Gaggauta Tura

Shirye Don Faɗaɗawa

Bin Ka’ida Tabbas

Na'urorin transceiver na OSFP 800G suna da layukan lantarki 8 na 100G PAM4. Dukkan na'urorin da ke cikin jerin suna amfani da jikin OSFP ɗaya mai fikafikan sanyaya. Zaɓi na'urar bisa tsawon hanyar haɗi, daga 50 m a kan fiber na multimode zuwa 10 km a kan fiber na single-mode.

DR8 da 2×DR4 suna aiki har zuwa 500 m ta mahaɗan MPO-12 guda biyu. DR8 hanyar haɗi ɗaya ce ta 800G. 2×DR4 hanyoyin haɗi biyu ne masu zaman kansu na 400G. DR8+ (2 km) da DR8++ (10 km) suna amfani da mahaɗan MPO-12 guda biyu iri ɗaya. 2×FR4 (2 km) da 2×LR4 (10 km) na'urorin twin-port ne masu mahaɗan duplex LC guda biyu. VR8 tana aiki har zuwa 50 m a kan fiber na multimode na OM4. Dukkan na'urori suna aiki daga 0 °C zuwa +70 °C.

Lambar tantancewa: an jera kowace na'ura da lambar tantancewa ta NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) da ta gama-gari (-CG). Ana samun lambar tantancewa ta musamman idan an buƙata. Lambar tantancewa tana canza shaidar EEPROM kawai.

Don kamfanonin sadarwa da masu gudanar da cibiyoyin bayanai a Afirka. Yi amfani da waɗannan na’urorin 800G don hanyoyin haɗi daga 50 m (multimode) zuwa 10 km (single-mode).
Lantarki
Mahaɗar HostOSFP (layuka 8 × 100G PAM4)
Amfani da WutaDR8+: <16 W
DR8++: <18.5 W
2×FR4: <16 W
VR8: <13.5 W
Sauran nau'o'i: duba takardar bayanai
Haske
Tsawon Raƙuman HaskeDR8, 2×DR4, DR8+, DR8++: 1310 nm
2×FR4, 2×LR4: CWDM4 (1271 / 1291 / 1311 / 1331 nm)
VR8: 850 nm VCSEL
NisaVR8: 50 m OM4 / 30 m OM3
DR8, 2×DR4: 500 m SMF
DR8+, 2×FR4: 2 km SMF
DR8++, 2×LR4: 10 km SMF
Nau'in FiberOS2 single-mode (dukkan banda VR8)
OM3 / OM4 multimode (VR8)
MahaɗaiMPO-12 biyu (DR8, 2×DR4, DR8+, DR8++)
MPO-12 APC biyu (VR8)
Duplex LC biyu (2×FR4, 2×LR4)
Ma'aunin Media800GBASE-DR8 / 2×400GBASE-DR4 (IEEE 802.3df)
2×400GBASE-FR4 (IEEE 802.3cu)
2×400G-LR4-10 (100G Lambda MSA)
VR8: 2×400GBASE-SR4 (IEEE 802.3db)
Tallafin Yarjejeniya (Protocol)
Ethernet800 GbE, ko 2 × 400 GbE (nau'o'in twin-port)
Lambar Tantancewa da Jituwa
Daidaitattun Lambobin TantancewaNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), ta gama-gari (-CG). Na'urar haske ɗaya ce ga kowace lambar tantancewa. Shaidar EEPROM kawai ce ta bambanta.
Lambar Tantancewa ta MusammanAna samu idan an buƙata don sauran masu ƙera switch.
Muhalli
Zafin Aiki0 °C zuwa +70 °C (Kasuwanci)
Zafin Ajiya-40 °C zuwa +85 °C
Bin MSAOSFP MSA Rev 5.0+
Bin Ƙa'idoji
Ma'auniIEEE 802.3cu / 802.3db / 802.3df, 100G Lambda MSA, OSFP MSA, CMIS 5.x, RoHS3
Ya bi RoHSEe
OSFP 800G DR8 (MPO-12 biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-DR8-2MPO-FN-CNOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-DR8-2MPO-FN-CCOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-DR8-2MPO-FN-CJOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-DR8-2MPO-FN-CAOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-DR8-2MPO-FN-CHOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-DR8-2MPO-FN-CDOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-DR8-2MPO-FN-CFOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-DR8-2MPO-FN-CGOSFP 800G DR8, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G 2×DR4 Twin-Port (MPO-12 biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-2DR4-2MPO-FN-CNOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-2DR4-2MPO-FN-CCOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-2DR4-2MPO-FN-CJOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-2DR4-2MPO-FN-CAOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-2DR4-2MPO-FN-CHOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-2DR4-2MPO-FN-CDOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-2DR4-2MPO-FN-CFOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-2DR4-2MPO-FN-CGOSFP 800G 2×DR4 Twin-Port (2 × 400G), MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 500 m SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G DR8+ Ƙarin Nisa (MPO-12 biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-DR8K2-2MPO-FN-CNOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-DR8K2-2MPO-FN-CCOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-DR8K2-2MPO-FN-CJOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-DR8K2-2MPO-FN-CAOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-DR8K2-2MPO-FN-CHOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-DR8K2-2MPO-FN-CDOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-DR8K2-2MPO-FN-CFOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-DR8K2-2MPO-FN-CGOSFP 800G DR8+, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 2 km SMF, <16 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G DR8++ Nisa Mai Tsawo (MPO-12 biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-DR8K10-2MPO-FN-CNOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-DR8K10-2MPO-FN-CCOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-DR8K10-2MPO-FN-CJOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-DR8K10-2MPO-FN-CAOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-DR8K10-2MPO-FN-CHOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-DR8K10-2MPO-FN-CDOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-DR8K10-2MPO-FN-CFOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-DR8K10-2MPO-FN-CGOSFP 800G DR8++, MPO-12 biyu, Ethernet, Mai fikafikan sanyaya, 1310 nm, 10 km SMF, <18.5 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G 2×FR4 CWDM4 Twin-Port (Duplex LC biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-2FR4-2LC-CNOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-2FR4-2LC-CCOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-2FR4-2LC-CJOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-2FR4-2LC-CAOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-2FR4-2LC-CHOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-2FR4-2LC-CDOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-2FR4-2LC-CFOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-2FR4-2LC-CGOSFP 800G 2×FR4 CWDM4, Duplex LC biyu, Ethernet, 2 km SMF, <16 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G 2×LR4 Twin-Port (Duplex LC biyu, single-mode)
Lambar SasheBayani
PO-OS-800GE-2LR4-2LC-FN-CNOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-2LR4-2LC-FN-CCOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-2LR4-2LC-FN-CJOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-2LR4-2LC-FN-CAOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-2LR4-2LC-FN-CHOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-2LR4-2LC-FN-CDOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-2LR4-2LC-FN-CFOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-2LR4-2LC-FN-CGOSFP 800G 2×LR4, Duplex LC biyu, Ethernet, Mai fikafikan sanyaya, CWDM4, 10 km SMF, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)
OSFP 800G VR8 Multimode (2×400G SR4, MPO-12 APC biyu)
Lambar SasheBayani
PO-OS-800GE-VR8-2MPO-CNOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta NVIDIA
PO-OS-800GE-VR8-2MPO-CCOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Cisco
PO-OS-800GE-VR8-2MPO-CJOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Juniper
PO-OS-800GE-VR8-2MPO-CAOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Arista
PO-OS-800GE-VR8-2MPO-CHOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta HPE / Aruba
PO-OS-800GE-VR8-2MPO-CDOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Dell
PO-OS-800GE-VR8-2MPO-CFOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, da lambar tantancewa ta Fortinet
PO-OS-800GE-VR8-2MPO-CGOSFP 800G VR8 (2×400G SR4) Multimode, MPO-12 APC biyu, Ethernet, 850 nm, 50 m OM4 / 30 m OM3, <13.5 W, 0–70 °C, na gama-gari (ba tare da lambar tantancewa ba)