Vipitishi-Vipokezi Vinavyochomekwa vya QSFP28 100G

Vipitishi-vipokezi vya QSFP28 100G: SR4, DR1, FR1, CWDM4, PSM4, LR1, LR4, ER4 na ZR4. 100 m multimode hadi 80 km single-mode.
  • 100G katika lango moja la QSFP28
  • Umbali: 100 m (OM4), 500 m, 2 km, 10 km, 40 km na 80 km (single-mode)
  • DR1, FR1 na LR1 huunganishwa na lane moja ya moduli ya 400G DR4, DR4+ au DR4++
  • MPO-12 (SR4), MPO-12 APC (PSM4) au duplex LC (moduli nyingine zote)
  • Usimbaji kwa NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, wa jumla au maalum
  • Kiwango cha joto cha kibiashara: 0 °C hadi +70 °C
  • QSFP28 MSA, usimamizi wa host wa SFF-8636

Imebuniwa Kuongeza Ufanisi

Iliyowasilishwa kwa Uhakika

Ununuzi Umefanywa Rahisi

Tayari kwa Utekelezaji wa Haraka

Tayari kwa Kupanua Uwezo

Uzingatiaji Umehakikishwa

Vipitishi-vipokezi vya QSFP28 100G vina lane 4 za umeme za 25G NRZ. Swichi nyingi za vituo vya data, kampasi na watoa huduma za mawasiliano zina milango ya QSFP28.

SR4 hufanya kazi kwa umbali wa 100 m kwenye nyuzi za multimode za OM4 kupitia kiunganishi kimoja cha MPO-12. DR1 (500 m), FR1 (2 km) na LR1 (10 km) hutuma 100G kwenye urefu mmoja wa wimbi. Kila moja inaweza kuunganishwa na lane moja ya moduli ya 400G DR4, DR4+ au DR4++ kupitia kebo ya breakout ya MPO-hadi-LC.

CWDM4 (2 km) na LR4 (10 km) hutuma urefu 4 wa mawimbi kupitia kiunganishi kimoja cha duplex LC. PSM4 hufanya kazi kwa umbali wa 2 km au 10 km kupitia kiunganishi cha MPO-12 APC. Unaweza kugawanya kiungo cha PSM4 kuwa 4 × 25G. ER4 hufanya kazi kwa umbali wa 40 km. ZR4 hufanya kazi kwa umbali wa 80 km ikiwa na FEC ya host. Moduli zote hufanya kazi kuanzia 0 °C hadi +70 °C.

Usimbaji: kila moduli imeorodheshwa na usimbaji wa NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) na wa jumla (-CG). Usimbaji maalum unapatikana kwa ombi. Usimbaji hubadilisha utambulisho wa EEPROM pekee.

Kwa watoa huduma za mawasiliano na waendeshaji wa vituo vya data barani Afrika. Tumia moduli hizi za 100G kwa viungo vya vituo vya data, kampasi na metro kuanzia 100 m (multimode) hadi 80 km (single-mode).
Umeme
Kiolesura cha HostQSFP28 (lane 4 × 25G NRZ)
Uashiriaji4 × 25G NRZ ya macho (SR4, PSM4, CWDM4, LR4, ER4, ZR4)
1 × 100G PAM4 ya macho yenye gearbox ya ndani (DR1, FR1, LR1)
Macho
Urefu wa MawimbiSR4: 850 nm VCSEL
DR1, PSM4: 1310 nm
FR1, LR1: 1311 nm
CWDM4: 1271 / 1291 / 1311 / 1331 nm
LR4, ER4, ZR4: LAN-WDM 1295.56 / 1300.05 / 1304.58 / 1309.14 nm
UmbaliSR4: 100 m OM4 (70 m OM3)
DR1: 500 m SMF
FR1, CWDM4: 2 km SMF
PSM4: 2 km au 10 km SMF
LR1, LR4: 10 km SMF
ER4: 40 km SMF
ZR4: 80 km SMF ikiwa RS-FEC ya host imewashwa, 60 km bila
Aina ya NyuziOM3 / OM4 multimode (SR4)
OS2 single-mode (aina nyingine zote)
ViunganishiMPO-12 (SR4)
MPO-12 APC (PSM4)
Duplex LC (DR1, FR1, LR1, CWDM4, LR4, ER4, ZR4)
Viwango vya Media100GBASE-SR4 (IEEE 802.3bm)
100G PSM4 MSA
100GBASE-DR (IEEE 802.3cd)
100GBASE-FR1 / LR1 (IEEE 802.3cu)
100G CWDM4 MSA
100GBASE-LR4 / ER4 (IEEE 802.3ba)
100G ZR4 (kiwango cha sekta)
Itifaki Zinazosaidiwa
Ethernet100 GbE (SKU zote)
Nambari ya Sehemu ya Rejea ya NVIDIAMMA1B00-C100D (SR4)
MMS1V70-CM (DR1)
Usimbaji na Utangamano
Usimbaji wa KawaidaNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), wa jumla (-CG). Moduli ya macho ni ileile kwa kila usimbaji. Utambulisho wa EEPROM pekee ndio unaotofautiana.
Usimbaji MaalumUnapatikana kwa ombi kwa watengenezaji wengine wa swichi.
Mazingira
Joto la Uendeshaji0 °C hadi +70 °C (Kibiashara)
Joto la Uhifadhi-40 °C hadi +85 °C
Utiifu wa MSAQSFP28 MSA
Utiifu
ViwangoIEEE 802.3ba / 802.3bm / 802.3cd / 802.3cu, CWDM4 MSA, PSM4 MSA, QSFP28 MSA, SFF-8636, RoHS3
Inatii RoHSNdiyo
QSFP28 100G SR4 Multimode (MPO-12)
Nambari ya SehemuMaelezo
PO-QS-100GE-SR4-MPO-CNQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa NVIDIA (rejea MMA1B00-C100D)
PO-QS-100GE-SR4-MPO-CCQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-SR4-MPO-CJQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-SR4-MPO-CAQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-SR4-MPO-CHQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-SR4-MPO-CDQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-SR4-MPO-CFQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-SR4-MPO-CGQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G DR1 Lambda Moja (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-DR-LC-CNQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa NVIDIA (rejea MMS1V70-CM)
PO-QS-100GE-DR-LC-CCQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-DR-LC-CJQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-DR-LC-CAQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-DR-LC-CHQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-DR-LC-CDQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-DR-LC-CFQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-DR-LC-CGQSFP28 100 GbE DR1 Lambda Moja, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G FR1 Lambda Moja (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-FR-LC-CNQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-FR-LC-CCQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-FR-LC-CJQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-FR-LC-CAQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-FR-LC-CHQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-FR-LC-CDQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-FR-LC-CFQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-FR-LC-CGQSFP28 100 GbE FR1 Lambda Moja, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G CWDM4 (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-CW4-LC-CNQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-CW4-LC-CCQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-CW4-LC-CJQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-CW4-LC-CAQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-CW4-LC-CHQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-CW4-LC-CDQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-CW4-LC-CFQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-CW4-LC-CGQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G PSM4 (MPO-12 APC, single-mode sambamba)
Nambari ya SehemuMaelezo
PO-QS-100GE-PSM4K2-MPO-CNQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-PSM4K2-MPO-CCQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-PSM4K2-MPO-CJQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-PSM4K2-MPO-CAQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-PSM4K2-MPO-CHQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-PSM4K2-MPO-CDQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-PSM4K2-MPO-CFQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-PSM4K2-MPO-CGQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 2 km SMF, 0–70 °C, ya jumla (bila usimbaji)
PO-QS-100GE-PSM4K10-MPO-CNQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-PSM4K10-MPO-CCQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-PSM4K10-MPO-CJQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-PSM4K10-MPO-CAQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-PSM4K10-MPO-CHQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-PSM4K10-MPO-CDQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-PSM4K10-MPO-CFQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-PSM4K10-MPO-CGQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G sambamba, 10 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G LR1 Lambda Moja (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-LR-LC-CNQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-LR-LC-CCQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-LR-LC-CJQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-LR-LC-CAQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-LR-LC-CHQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-LR-LC-CDQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-LR-LC-CFQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-LR-LC-CGQSFP28 100 GbE LR1 Lambda Moja, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G LR4 (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-LR4-LC-CNQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-LR4-LC-CCQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-LR4-LC-CJQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-LR4-LC-CAQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-LR4-LC-CHQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-LR4-LC-CDQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-LR4-LC-CFQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-LR4-LC-CGQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G ER4 (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-ER4-LC-CNQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-ER4-LC-CCQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-ER4-LC-CJQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-ER4-LC-CAQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-ER4-LC-CHQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-ER4-LC-CDQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-ER4-LC-CFQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-ER4-LC-CGQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, ya jumla (bila usimbaji)
QSFP28 100G ZR4 (Duplex LC, single-mode)
Nambari ya SehemuMaelezo
PO-QS-100GE-ZR4-LC-CNQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa NVIDIA
PO-QS-100GE-ZR4-LC-CCQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa Cisco
PO-QS-100GE-ZR4-LC-CJQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa Juniper
PO-QS-100GE-ZR4-LC-CAQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa Arista
PO-QS-100GE-ZR4-LC-CHQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa HPE / Aruba
PO-QS-100GE-ZR4-LC-CDQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa Dell
PO-QS-100GE-ZR4-LC-CFQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, imesimbwa kwa Fortinet
PO-QS-100GE-ZR4-LC-CGQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF ikiwa na RS-FEC ya host (60 km bila), 0–70 °C, ya jumla (bila usimbaji)