# Vipitishi-Vipokezi Vinavyochomekwa vya OSFP 400G


Vipitishi-vipokezi vya OSFP-RHS 400G: DR4, FR4, LR4 na VR4. Lane 4 × 100G, 50 m multimode hadi 10 km single-mode.


Vipitishi-vipokezi vya OSFP 400G vina sehemu ya juu bapa kwa milango ya OSFP-RHS (riding heat sink). Vina lane 4 za umeme za 100G PAM4. Vitumie katika adapta za mtandao za NVIDIA ConnectX-7 na DPU za BlueField-3 kwa NDR InfiniBand na 400 GbE.
DR4 hufanya kazi kwa umbali wa 500 m kwenye nyuzi za single-mode kupitia kiunganishi kimoja cha MPO-12. Inaweza kuunganishwa na lango moja la moduli ya swichi ya 800G 2×DR4. FR4 (2 km) na LR4 (10 km) hutumia kiunganishi kimoja cha duplex LC. VR4 hufanya kazi kwa umbali wa 50 m kwenye nyuzi za multimode za OM4 kupitia kiunganishi cha MPO-12 APC. VR4 inapatikana kwa InfiniBand na Ethernet, au kwa Ethernet pekee. Moduli zote hufanya kazi kuanzia 0 °C hadi +70 °C.
Usimbaji: kila moduli imeorodheshwa na usimbaji wa NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) na wa jumla (-CG). Usimbaji maalum unapatikana kwa ombi. Usimbaji hubadilisha utambulisho wa EEPROM pekee.


## Images


* ![Kipitishi-kipokezi cha OSFP 400G LR4 duplex LC, kishikio cha kuvuta cha buluu, 10 km single-mode](scalefibre-osfp-400g-lr4-duplex-lc-transceiver-10km-blue-tab.webp)

* ![Kipitishi-kipokezi cha OSFP 400G DR4 MPO-12, kishikio cha kuvuta cha njano, 500 m single-mode](scalefibre-osfp-400g-dr4-mpo-transceiver-500m-yellow-tab.webp)

* ![Kipitishi-kipokezi cha OSFP 400G FR4 duplex LC, kishikio cha kuvuta cha kijani, 2 km single-mode](scalefibre-osfp-400g-fr4-duplex-lc-transceiver-2km-green-tab.webp)

* ![Kipitishi-kipokezi cha OSFP 400G VR4 MPO-12 multimode, kishikio cha kuvuta cha rangi ya beige, 50 m OM4](scalefibre-osfp-400g-vr4-multimode-transceiver-beige-tab.webp)



## Features


* 400G kwenye lane 4 × 100G PAM4 katika kasha la OSFP-RHS lenye sehemu ya juu bapa
* Umbali: 50 m (OM4), 500 m, 2 km na 10 km (single-mode)
* MPO-12 (DR4), MPO-12 APC (VR4) au duplex LC (FR4, LR4)
* Usimbaji kwa NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, wa jumla au maalum
* Kiwango cha joto cha kibiashara: 0 °C hadi +70 °C
* OSFP MSA, usimamizi wa host wa CMIS 5.x

## Configurations
### OSFP 400G DR4 (MPO-12, single-mode)
| Part Number | Description |
| --- | --- |
| PO-OS-400GE-DR4-MPO-CN | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa NVIDIA (rejea MMS4X00-NS400) |
| PO-OS-400GE-DR4-MPO-CC | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Cisco |
| PO-OS-400GE-DR4-MPO-CJ | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Juniper |
| PO-OS-400GE-DR4-MPO-CA | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Arista |
| PO-OS-400GE-DR4-MPO-CH | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa HPE / Aruba |
| PO-OS-400GE-DR4-MPO-CD | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Dell |
| PO-OS-400GE-DR4-MPO-CF | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, imesimbwa kwa Fortinet |
| PO-OS-400GE-DR4-MPO-CG | OSFP 400G DR4 Lango Moja, MPO-12, Ethernet, 1310 nm, 500 m SMF, 0–70 °C, ya jumla (bila usimbaji) |
### OSFP 400G FR4 CWDM4 (Duplex LC, single-mode)
| Part Number | Description |
| --- | --- |
| PO-OS-400GE-FR4-LC-CN | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa NVIDIA |
| PO-OS-400GE-FR4-LC-CC | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa Cisco |
| PO-OS-400GE-FR4-LC-CJ | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa Juniper |
| PO-OS-400GE-FR4-LC-CA | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa Arista |
| PO-OS-400GE-FR4-LC-CH | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba |
| PO-OS-400GE-FR4-LC-CD | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa Dell |
| PO-OS-400GE-FR4-LC-CF | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, imesimbwa kwa Fortinet |
| PO-OS-400GE-FR4-LC-CG | OSFP 400G FR4 CWDM4, Duplex LC, Ethernet, 2 km SMF, 0–70 °C, ya jumla (bila usimbaji) |
### OSFP 400G LR4 (Duplex LC, single-mode)
| Part Number | Description |
| --- | --- |
| PO-OS-400GE-LR4-LC-CN | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa NVIDIA |
| PO-OS-400GE-LR4-LC-CC | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa Cisco |
| PO-OS-400GE-LR4-LC-CJ | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa Juniper |
| PO-OS-400GE-LR4-LC-CA | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa Arista |
| PO-OS-400GE-LR4-LC-CH | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa HPE / Aruba |
| PO-OS-400GE-LR4-LC-CD | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa Dell |
| PO-OS-400GE-LR4-LC-CF | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, imesimbwa kwa Fortinet |
| PO-OS-400GE-LR4-LC-CG | OSFP 400G LR4, Duplex LC, Ethernet, CWDM4, 10 km SMF, 0–70 °C, ya jumla (bila usimbaji) |
### OSFP 400G VR4 Multimode (MPO-12 APC)
| Part Number | Description |
| --- | --- |
| PO-OS-400GIE-VR4-MPO-CN | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa NVIDIA (rejea MMA4Z00-NS400) |
| PO-OS-400GIE-VR4-MPO-CC | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Cisco |
| PO-OS-400GIE-VR4-MPO-CJ | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Juniper |
| PO-OS-400GIE-VR4-MPO-CA | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Arista |
| PO-OS-400GIE-VR4-MPO-CH | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa HPE / Aruba |
| PO-OS-400GIE-VR4-MPO-CD | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Dell |
| PO-OS-400GIE-VR4-MPO-CF | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Fortinet |
| PO-OS-400GIE-VR4-MPO-CG | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, IB + Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, ya jumla (bila usimbaji) |
| PO-OS-400GE-VR4-MPO-CN | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa NVIDIA (rejea MMA4Z00-NS400-T) |
| PO-OS-400GE-VR4-MPO-CC | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Cisco |
| PO-OS-400GE-VR4-MPO-CJ | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Juniper |
| PO-OS-400GE-VR4-MPO-CA | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Arista |
| PO-OS-400GE-VR4-MPO-CH | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa HPE / Aruba |
| PO-OS-400GE-VR4-MPO-CD | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Dell |
| PO-OS-400GE-VR4-MPO-CF | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, imesimbwa kwa Fortinet |
| PO-OS-400GE-VR4-MPO-CG | OSFP 400G VR4 SR4 Multimode, MPO-12 APC, Ethernet, 850 nm, 50 m OM4, <8 W, 0–70 °C, ya jumla (bila usimbaji) |


## Specifications
### Umeme

| Item | Value |
| --- | --- |
| Kiolesura cha Host | OSFP-RHS sehemu ya juu bapa (lane 4 × 100G PAM4) |
| Uashiriaji | PAM4 ya 100G kwa kila lane |
| Matumizi ya Nishati | VR4: <8 W<br>DR4, FR4, LR4: angalia karatasi ya data |
### Macho

| Item | Value |
| --- | --- |
| Urefu wa Mawimbi | DR4: 1310 nm<br>FR4, LR4: CWDM (1271 / 1291 / 1311 / 1331 nm)<br>VR4: 850 nm VCSEL |
| Umbali | VR4: 50 m OM4<br>DR4: 500 m SMF<br>FR4: 2 km SMF<br>LR4: 10 km SMF |
| Aina ya Nyuzi | OS2 single-mode (DR4, FR4, LR4)<br>OM4 multimode (VR4) |
| Viunganishi | MPO-12 (DR4)<br>MPO-12 APC (VR4)<br>Duplex LC (FR4, LR4) |
| Viwango vya Media | 400GBASE-DR4 (IEEE 802.3bs)<br>400GBASE-FR4 (IEEE 802.3cu)<br>400G-LR4-10 (100G Lambda MSA)<br>400GBASE-VR4 (IEEE 802.3db) |
### Itifaki Zinazosaidiwa

| Item | Value |
| --- | --- |
| Ethernet | 400 GbE (SKU zote) |
| InfiniBand | NDR (aina ya VR4 IB+ETH pekee) |
| Nambari ya Sehemu ya Rejea ya NVIDIA | MMS4X00-NS400 (DR4)<br>MMA4Z00-NS400 (VR4 IB+ETH)<br>MMA4Z00-NS400-T (VR4 ETH) |
### Usimbaji na Utangamano

| Item | Value |
| --- | --- |
| Usimbaji wa Kawaida | NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), wa jumla (-CG). Moduli ya macho ni ileile kwa kila usimbaji. Utambulisho wa EEPROM pekee ndio unaotofautiana. |
| Usimbaji Maalum | Unapatikana kwa ombi kwa watengenezaji wengine wa swichi. |
### Mazingira

| Item | Value |
| --- | --- |
| Joto la Uendeshaji | 0 °C hadi +70 °C (Kibiashara) |
| Joto la Uhifadhi | -40 °C hadi +85 °C |
| Utiifu wa MSA | OSFP MSA (RHS sehemu ya juu bapa) |
### Utiifu

| Item | Value |
| --- | --- |
| Viwango | IEEE 802.3bs / 802.3cu / 802.3db, 100G Lambda MSA, OSFP MSA, CMIS 5.x, RoHS3 |
| Inatii RoHS | Ndiyo |